How to Change the Mould on a Foil Container Press
To change the mould on a foil container press, prepare the next mould while the old one is still running, lock the press out to swap the two, then set the new mould’s clamping, shut height and feed before trial strokes prove it and the settings are recorded.
Step 1: Prepare the Next Mould Before Stopping the Press
Before the press stops, the next mould should be at the press, inspected, and with everything it needs laid out beside it. Bring it over on the lifting gear you will use to set it, and check that the draw and cutting edges are clean and free of burrs or nicks and that the air ejection ports are clear.
Lay out the clamps and bolts, the spanners, the safety blocks, any shims, and the setting sheet from the last time this mould ran. If the new container needs a different coil width or alloy, have that coil at the decoiler.
Step 2: Stop the Press and Lock It Out
Stop the press with the mould closed at the bottom of the stroke, wait for the flywheel to come to rest, then lock out the main power isolator and shut off and bleed the air supply to the clutch, brake and air ejection. Verify the press cannot start before anyone reaches into the mould area, and keep it locked out for as long as hands are in there.
Inch mode and two-hand control do not make the die area safe. Whenever the ram is up with hands in the die area, put a safety block between the ram and the bolster, which the US mechanical power press rule requires whenever dies are being adjusted or repaired in the press.
The press may be re-energised only for the moments a step needs it, such as raising or lowering the ram to position it. Lock out again before anyone reaches back in.
Step 3: Disconnect the Feeder, Oiler and Air Ejection
Release everything that ties the mould to the line: the foil strip, the air ejection hoses, and any sensor cables or oil lines mounted on the mould. Cut the foil between the feeder and the mould and pull the tail out of the mould.
Unplug the air ejection hoses at the mould fittings once the air has been bled in Step 2. Most oilers sit upstream of the feeder and only need switching off. If yours has nozzles or rollers fixed to the mould, unhook them now, and move the stacker take-off back far enough to clear the lifting path.
Step 4: Unclamp and Remove the Old Mould
Release the ram clamps first, while the mould is still closed and the upper half is resting on the lower half, so the upper half has nowhere to fall when it comes free of the ram. Then raise the ram clear, lock out again, and release the bolster clamps.
Take the clamps out of their slots if they are in the mould’s path. Lift the mould out as one closed set on its lifting points, with lifting gear rated for its marked weight, and set it down on a clean stand. Note anything you saw go wrong in the last run, so the mould goes for maintenance with the reason attached.
Step 5: Clean the Bolster and Ram Faces
Wipe the bolster and ram faces free of oil and foil fines, stone off any burrs, and blow out the T-slots.
While the faces are bare, check that the locating keys, pins and centre marks are undamaged and that the bolster’s air ports, where the press has them, are clear.
Step 6: Install and Centre the New Mould
Set the new mould on the bolster on its locating keys or pins, with its centre line on the press centre line, and turned so the foil enters from the feeder side and the containers leave toward the stacker.
Before the ram comes down onto the new mould, raise the shut-height adjustment so the ram cannot close below the mould’s closed height. Inch the ram down onto the mould, lock out, clamp the upper half to the ram, and leave the lower clamps snug but not tight.
Cycle the press slowly a few times so the guide pillars pull the lower half into line with the upper half, then lock out and tighten the lower clamps.
Step 7: Clamp the Mould at the Right Force
Clamp the mould with a total clamping force of about 20 % of the press’s capacity, and with ram clamps rated at four times the mould weight between them, so it cannot shift under the stroke. These are two clamp makers’ rules of thumb, sized on different bases.
A 200-ton press therefore needs about 40 tons of total clamping force under the 20 % rule. For the ram clamps, multiply the mould weight by four and divide by the number of clamps, then fit the same number of clamps on the bolster to balance the load.
The four-times rule is written for moderate press speeds, and the press maker’s own figure overrides either rule. Several smaller clamps hold better than a few large ones. Tighten the bolts evenly, in a cross pattern, to the clamp maker’s torque.
Step 8: Set the Shut Height
With the mould clamped and the ram at top dead centre, bring the shut height down in small steps until the mould closes fully at the bottom of the stroke. Always approach the final setting from the open side and in the same direction, so the play in the adjusting screw is taken up the same way every time.
Start from the shut height recorded on the mould’s setting sheet, and check whether the mould has been reworked since that figure was written.
Set the stroke rate you will produce at before the final check, because a change of press speed changes where the mould closes. Once the shut height is right, leave it: forming problems are corrected in the mould with shims, and the shut height only changes when the mould or the foil gauge does.
Step 9: Reset the Feeder for the New Container
The new container changes three things on the feed side: how far the foil advances per stroke, the height at which it enters the mould, and where the oil, air and stacker have to act.
Feed Length
Feed length is the distance the foil must advance per stroke so that each new blank starts just past the last one: the blank length along the strip plus the web left between blanks. On a multi-cavity mould, cavities set side by side across the strip do not change it; cavities set one behind another along the strip multiply it by the number of rows.
Enter the value from the mould’s setting sheet or drawing on the feeder controller, then check it on the first strokes. The web between blanks should be even: too short a feed cuts into the previous blank, and too long a feed wastes foil on every stroke.
Feed Height
Set the feeder so the foil runs level into the mould at the height of the lower half’s cutting edge, neither dragged up nor pushed down at the entry. Reset the feeder height every time the new mould’s lower half is a different height.
Set the strip guides to the new coil width with a little clearance.
Oiler, Air Ejection and Stacker
- Oiler: match the oiled width to the new strip, shut off any nozzles or roller sections outside it, and set the oil quantity the setting sheet records for this mould.
- Air ejection: reconnect the air to the mould fittings, aim each blow-off nozzle so its cavity’s container leaves toward the stacker, and time the blast to fire after the mould has opened.
- Stacker: reset the guides or chute to the new container size and the count per stack.
- Scrap handling: reset the skeleton winder or chopper to the new web width.
- Guards: put every guard back before the first powered stroke.
Step 10: Run Trial Strokes and Check the First Containers
First Strokes by Inching
With the guards on and nobody inside them, inch the press through one full stroke without foil and watch the mould close and open cleanly. Then thread the foil, single-stroke a few containers, run continuously at low speed, and only then bring the press up to production speed.
Production is never run in inch mode. If anything needs adjusting inside the mould, stop and lock out again.
Checking the First Containers
Check the first containers from every cavity, side by side, before production restarts:
- Depth and shape: full depth, square corners, and the same shape from each cavity.
- Walls: even pleats on a wrinkle-wall container; no wrinkles on a smooth-wall one.
- Rim: curled evenly all the way round, with no flat spots or splits.
- Foil: no tears or pinholes, especially at the corners where the draw is deepest.
- Edge: trimmed clean, with no burrs or hanging slivers.
- Stacking: the containers nest and come apart without sticking.
On smooth-wall containers that will be lidded or film-sealed, look hard at the corners of the rim. Restart production once every cavity passes over several consecutive strokes at production speed.
Step 11: Record the Settings
Write down every setting the mould ended the trial with, so the next change starts from known values:
- Shut height: the final reading on the press scale.
- Feed: feed length, feeder height and strip guide width.
- Speed: the stroke rate the shut height was set at.
- Clamping: clamp positions and bolt torque.
- Oiler and air: oil quantity, nozzle positions and air ejection timing.
- Stacker: guide positions and count per stack.
- Coil: the foil alloy, temper, gauge and width the mould ran on.
- Adjustments: anything changed during the trial, and why.
Keep the sheet with the mould rather than with the press, so it travels to whichever press runs the mould next.