How to Calculate Press Tonnage for Foil Container Production
To calculate the press tonnage a foil container mould needs, add the blanking force, the drawing force and the blank holder force for one cavity, multiply by the number of cavities, and divide by the share of the press’s rating you are prepared to use.
The result is then compared with the force the press is rated to deliver near the bottom of its stroke, where the foil is actually cut and drawn.
The Press Tonnage Formula for a Foil Container
The tonnage one stroke needs is the sum of the three forces that act on the foil during that stroke:
Total force per cavity = blanking force + drawing force + blank holder force
If the die also has spring pads, strippers or lifters, the force needed to compress them belongs in the total too. The most direct way to find that extra load is to cycle the mould in the press with no foil and read the tonnage monitor.
Work in one unit system throughout. A force in newtons divided by 9,807 gives metric tonnes-force, and divided by 8,896 gives US (short) tons; one metric tonne-force is about 1.10 US tons. If your strength values are in kgf/mm², multiplying by length and thickness in millimetres gives kilograms-force directly, and 1,000 kgf is one metric tonne-force.
Blanking Force
The blanking force is the length of the cut edge times the foil thickness times the foil’s shear strength:
F = L × t × τ
Here L is the perimeter of the blank in mm, t is the foil thickness in mm, and τ is the ultimate shear strength in N/mm². For a container mould, L is the outline of the blank the cutting edge trims from the strip.
Drawing Force
The drawing force for a round shell is estimated with the textbook formula:
F = π × Dp × t × TS × (Db / Dp − 0.7)
Dp is the punch diameter, Db the blank diameter, t the foil thickness, and TS the foil’s tensile strength. The 0.7 is a friction correction subtracted from the draw ratio Db / Dp. Some calculator pages multiply the force by 0.7 instead, and below a draw ratio of 1.4 that version gives a higher figure than the textbook one.
Few published formulas cover rectangular or oval containers. For an estimate, use the diameters of round shapes with the same areas as the punch face and the blank, and confirm the figure on the first trial run.
Blank Holder Force
The blank holder force is usually taken as about one-third of the drawing force.
Thin foil often needs more than that. When the flange must come out flat, size the holder from a trial or from a measured load like the one in the worked example below.
Multiply by the Number of Cavities
Total tonnage is the per-cavity force times the number of cavities, because every cavity in a multi-cavity mould cuts and draws in the same stroke. Staggering the cutting edges does not lower that total.
Shear and Tensile Strength Values for Container Foil
Use the tensile strength on your foil supplier’s mill certificate for the drawing force, and about 0.6 times that tensile strength for the blanking shear strength. For reference, a granted US patent on laminated foil containers measured 8011 foil at 120 µm thickness at a tensile strength of 10.2 kgf/mm², which is about 100 MPa.
The 0.6 ratio is lower than the 0.8 × tensile rule many tonnage calculators use. In a 2022 study based on shear-punch tests, shear strength was about 59% of tensile strength for pure aluminium and about 67% for AA 6061.
Tonnage for Smooth-Wall vs Wrinkle-Wall Containers
A smooth-wall container needs more tonnage than a wrinkle-wall container of the same size.
No published source gives a multiplier for the difference. In the patent example above, a 300 kg blank holder load let the flange of a round foil-laminate cup wrinkle, and the test had to be run at 500 kg.
Add a Safety Margin and Round Up
Size the press so the calculated load uses only part of its rating. A common rule of thumb is to load a straight-sided press to no more than 80% of its rated tonnage and a C-frame press to no more than 60–70%. In practice, divide the calculated total by 0.8 for a straight-sided press, or by 0.6 to 0.7 for a C-frame press.
Round the result up to the next press size available. MTED’s C-type press starts at 45 t, and the H-type press comes in 63 t and 80 t models.
The rated tonnage applies only within a stated distance above the bottom of the stroke: 4 mm for MTED’s 63 t H-type model and 5 mm for the 80 t model. Compare your result with the force the press delivers at the point where the foil is cut and drawn.
Worked Example
The round foil-laminate cup from the US patent example above needs about 1 t of force per cavity. The cup is drawn from a 115 mm blank to a 70 mm opening and 30 mm depth, in 8011 foil 0.12 mm thick with a tensile strength of 10.2 kgf/mm². Only the metal layer is counted in the blanking and drawing forces, and the part is a cup rather than a takeaway tray, so read the method more than the figures.
Blanking force. The blank perimeter is π × 115 = 361 mm, and the shear strength is 0.59 × 10.2 = 6.02 kgf/mm²:
361 × 0.12 × 6.02 ≈ 261 kgf
Drawing force. The draw ratio Db / Dp is 115 / 70 = 1.643, so the friction-corrected term is 1.643 − 0.7 = 0.943:
π × 70 × 0.12 × 10.2 × 0.943 ≈ 254 kgf
Blank holder force. The one-third rule would give about 85 kgf, but the patent test needed 500 kgf to keep this laminate cup’s flange flat, so the example uses 500 kgf.
Total per cavity. The three forces add to about 1,015 kgf, or about 1.0 t:
261 + 254 + 500 ≈ 1,015 kgf
Six cavities. A six-cavity mould of this cup needs about 6.1 t:
6 × 1,015 ≈ 6,090 kgf
Margin. On a C-frame press, dividing 6.1 t by 0.7 and by 0.6 gives a required rating of about 9 to 10 t.
A 9 to 10 t requirement is about a fifth of a 45 t press. With foil this thin, the force sum rarely decides the press; bed area, frame stiffness and draw depth usually do.